Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170132013 - Two employees die, four others hurt in tank explosion

Accident Summary Nr: 170132013 -- Report ID: 1054118 -- Event Date: 02/05/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
12376541402/05/199317910Quality Tank & Construction Co
Inspection NrDate OpenedSICNAICSEstablishment Name
12376540602/05/199324990Georgia Pacific Corporation
Inspection NrDate OpenedSICNAICSEstablishment Name
12376541402/05/199317910Quality Tank & Construction Co

Abstract: At approximately 1:26 p.m., Employees #1 and #2 were working on top of a white liquor tank installing a blank into a line that had been drained for a shutdown. At the same time, Employees #3, #4, and #5 were working in the same vicinity. The liquor tank had been drained but as yet had not been opened or tested for air contaminates. As Employees #1 and #2 were installing the blank, Employee #4, a subcontractor, laid out a hole to install a ventilation fan at the top of the tank and then struck up his torch to cut into the top of the tank. At this point, a rumbling noise within the tank could be heard, followed by an explosion. Employees #1 and #2, who had been installing the blank, were blown off the tank, fell to the concrete surface 50 feet below, and died. Employee #3, a helper, was blown against a guardrail, sustaining a back injury. The two subcontractor employees, Employees #4 and #5, were caught in the blast. One went over the edge of the tank and was left hanging by the safety belt and the lanyard that he was using; he sustained a sprain and strained back. The other subcontractor employee was treated for bruising and shock. Employee #6, who was working on the ground in the vicinity of the tank, was caught in the blast as a manhole door flew open, blowing him some 40 feet across an open area.

Keywords: FLAMMABLE VAPORS, WORK RULES, EXPLOSION, TANK, VENTILATION, CONSTRUCTION, TORCH, BACK, FALL, SPRAIN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 123765414 Non Hospitalized injury Bruise/Contus/Abras Welders and cutters
2 123765406 Fatality Other Helpers, mechanics and repairers
3 123765406 Fatality Other Helpers, mechanics and repairers
4 123765406 Hospitalized injury Fracture Helpers, mechanics and repairers
5 123765406 Hospitalized injury Burn(Chemical) Helpers, mechanics and repairers
6 123765414 Non Hospitalized injury Bruise/Contus/Abras Welders and cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.