Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170126635 - Employee killed when backhoe falls on him

Accident Summary Nr: 170126635 -- Report ID: 0751910 -- Event Date: 08/01/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11504459608/02/199117310Central Iowa Electric

Abstract: Employee #1 was hauling dirt in the bucket of a loader/backhoe to fill small depressions in the ground around the concrete construction on the shoulder of a paved road. He was trying to dump part of the load when he lost control of the vehicle. The backhoe started down the slope and Employee #1 was thrown out because he did not have on his seat belt. He landed on the apron between the wing walls of a reinforced concrete box culvert. The backhoe fell on top of Employee #1, crushing his head and chest. He was killed.

Keywords: EJECTED, LOADER/BACKHOE, WORK RULES, EQUIPMENT OPERATOR, CONSTRUCTION, CRUSHED, SEAT BELT, LOST CONTROL, HIGHWAY SHOULDER, SLOPE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 115044596 Fatality Other Electricians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.