Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170126114 - ELECTRIC SHOCK - GROUND FAULT IN ELECTRIC SWITCH

Accident Summary Nr: 170126114 -- Report ID: 0751910 -- Event Date: 07/20/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11504678107/20/199220110John Morrell & Co.

Abstract: AN EMPLOYEE WAS OPERATING A HAM SKINNER. THE EMPLOYEE TRIED TO SHUT OFF THE MACHINE WITH ITS EMERGENCY STOP SWITCH AND RECEIVED AN ELECTRIC SHOCK. WATER AND PIECES OF MEAT RAN OUT OF THE SWITCH, WHICH HAD NOT BEEN INSTALLED IN A WATERTIGHT ENCLOSURE.

Keywords: E GI V, ELECTRICAL, ELECTRIC SWITCH, GROUND FAULT, WET OPERATION, EQUIPMENT GROUNDING, ELECTRIC SHOCK, ELECTRICAL BOX, EQUIPMENT APPROVAL, WATER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 115046781 Non Hospitalized injury Electric Shock Slicing and cutting machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.