Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170122022 - Employee dies in gasoline storage tank explosion

Accident Summary Nr: 170122022 -- Report ID: 0454714 -- Event Date: 05/08/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11105583605/09/199150930Jim Miller Excavating Co

Abstract: Employee #1 was struck by the metal end cap and the force of the explosion of a gasoline storage tank that he was cutting with an oxygen/butane cutting torch. He died.

Keywords: STORAGE TANK, TORCH, EXPLOSION, STRUCK BY, FLYING OBJECT, GASOLINE, CUTTING AND BURNING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111055836 Fatality Concussion Welders and cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.