Accident Summary Nr: 170121578 - Employee dies from ruptured spleen sustained in fall

Accident Summary Nr: 170121578 -- Report ID: 0453720 -- Event Date: 05/18/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
11115625305/31/199517410Grubbs Masonry

Abstract: At approximately 10:00 a.m. on May 18, 1995, Employee #1, a mason's assistant at the job site for the construction of a private residence, was disassembling a single buck scaffold. He was removing the planking from the scaffold work area when he fell approximately 3 feet, striking his stomach against the top cross member of the scaffold and rupturing his spleen. Employee #1 was transported by private vehicle to the hospital, where surgery was performed to remove his spleen. Hemorrhagic shock set in, causing disseminated intravascular clotting that prevented his blood from clotting. At 12:07 a.m. on May 19, 1995, Employee #1 hemorrhaged to death. There were no witness to the accident.

Keywords: BLOOD CLOT, SPLEEN, DISMANTLING, LOSS OF BLOOD, HEMORRHAGE, STRUCK AGAINST, CONSTRUCTION, RUPTURE, FALL, SCAFFOLD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111156253 Fatality Other Brickmasons and stonemasons apprentices

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close