Accident Summary Nr: 170121214 - Employee dies of injury sustained when struck by board

Accident Summary Nr: 170121214 -- Report ID: 0453710 -- Event Date: 03/11/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
1855215803/13/199224210A & D Lumber

Abstract: Employee #1 was operating the bull edger in a sawmill sawing white oak. Two coworkers were grading and separating lumber on the green chain. As the volume of lumber coming through the edger increased, the men on the green chain could not keep up and became frustrated. One of the coworkers walked away from the area; the other picked up a 1 in. by 6 in. board and threw it down across the table. At that instant a cant was in the edger being sawed. The thrown board entered the edger at the rear or exit end with the pressure feed rolls in the up position. The saws in the edger caught the board and propelled it through the edger atop the cant. The anti-kickback fingers were worn, too short, and improperly spaced. The board was ejected from the edger and hit Employee #1 in the abdomen. Employee #1 later died of internal bleeding from lacerations to the hepatic and superior mesenteric arteries as a result of a blunt trauma to the abdomen.

Keywords: BOARD, KICK BACK, ABDOMEN, LOSS OF BLOOD, INADEQUATE MAINT, WORK RULES, EQUIPMENT FAILURE, EDGER, SAWMILL, STRUCK BY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18552158 Fatality Other Sawing machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.