Accident Summary Nr: 170111231 - Elderly employee falls from scaffold and dies

Accident Summary Nr: 170111231 -- Report ID: 0111400 -- Event Date: 10/31/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
10917282510/31/199517410Sutton Corporation

Abstract: Employee #1 was working from a makeshift carpenter's bracket scaffold attached to the side of a future sea wall, inside a cofferdam. He was installing 2,700 lb granite blocks along with three other employees. The granite blocks were lowered into position with a crane and a nylon sling. But when the sling was removed from one block, the block tipped and fell onto the scaffold platform. The scaffold collapsed, sending Employee #1 22 ft to the bottom of the cofferdam. He died.

Keywords: LOAD SHIFT, CONSTRUCTION, SCAFFOLD COLLAPSE, ELDERLY, FALL, ELEVATED WORK PLAT, SCAFFOLD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 109172825 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.