Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 170110092 - Employee Killed When Crushed By Concrete Beam

Accident: 170110092 -- Report ID: 0111400 -- Event Date: 07/01/1992
InspectionOpen DateSICEstablishment Name
10753954607/01/19921622Kiewit/Atkinson/Kenny, A Joint Venture
InspectionOpen DateSICEstablishment Name
10753957907/09/19921542T.P.S. Construction Corporation
InspectionOpen DateSICEstablishment Name
10753956107/02/19927353S.G. Marino Crane Service Incorporated
InspectionOpen DateSICEstablishment Name
10753955307/01/19921542Barletta/O'Connell Joint Venture
InspectionOpen DateSICEstablishment Name
10753958707/01/19928741Icf Kaiser Engineers Of Massachusetts

Employees were constructing a precast concrete collar beam to support a manhole lid at the surface entrance of a tunnel shaft. The collar beam consisted of two 12 ft diameter precast concrete rings with a butyl rubber gasket between them. The day before the accident, the top segment was set on top of the base segment without the required gasket. The next day, a Link Belt LS-718 crawler crane was borrowed from the contractor at the adjacent site, and used to hoist the top segment 4 ft above the base segment. Three employees and an independent truck driver began applying the gasket material to the lip of the base segment with the top segment suspended directly above them. After warning the foreman of the hazard of working under the load, the crane operator activated a safety switch designed to engage the spring-applied brakes and locking pawls on all drums. The load came through the brake and pawl and pinned Employee #1's head and arms between the two segments. Later that afternoon, Employee #1 died of multiple head injuries caused by blunt trauma.

Keywords: head, suspended load, struck by, concrete beam, pinned, construction, crushed, arm, falling object

Employee Details
Employee # Inspection Age Sex Degree Nature Occupation
1 107539546 Fatality Other Occupation not reported
2 107539579 Occupation Not Listed
3 107539561 Occupation Not Listed
4 107539553 Occupation Not Listed
5 107539587 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close