Accident Summary Nr: 170105209 - Employee's finger amputated in power punch press

Accident Summary Nr: 170105209 -- Report ID: 0551800 -- Event Date: 09/27/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
12401205510/30/199537140Voyager Inc.

Abstract: At 3:05 p.m. on September 27, 1995, Employee #1 was operating a 10-ton full revolution #14 Press Rite mechanical power punch press. He said that he fed steel flat stock in the left side of the press through the die area to the stop on the right side of the press. He would cycle the press up to four or five times with the foot control, and then take a metal rake and push the cut-off parts out the right side of the machine. After a setup worker prepared the press to run, Employee #1 operated it for about a half hour and then noticed a part stuck in the die area. In trying to free it with the rake, he stood up from the stool on which he had been sitting and stepped on the foot trip. The press cycled and caught his right little finger in the die, amputating his ring finger at the first knuckle.

Keywords: DIE, AMPUTATED, FINGER, WORK RULES, FOOT CONTROL, LOCKOUT, POINT OF OPERATION, FOOT-POWERED PRESS, PUNCH PRESS, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 124012055 Non Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.