Accident Summary Nr: 170094254 - Employee killed when crushed between 2 dies

Accident Summary Nr: 170094254 -- Report ID: 0522500 -- Event Date: 12/23/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
10334061812/23/199335440Superior Die, Tool And Machine Company

Abstract: On December 23, 1993, Employee #1 and a coworker were unloading dies (19,300 to 23,000 lb) from a tractor trailer using an overhead crane. The dies were placed on wooden boards to keep them off the floor while being stored in preparation for use in machine presses. Two dies were set 2 to 3 ft apart. The second die was 40 in. wide, but was placed on two wooden boards at either end that were 29 in. and 9 in. wide respectively. The end of the second die, which was set on the 9 in. wide board, moved into the first die, crushing Employee #1 between the two dies. He died.

Keywords: DIE, UNSECURED, CAUGHT BETWEEN, CRUSHED, OFF LOADING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103340618 Fatality Puncture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.