Accident Summary Nr: 170093777 - Employee fatally struck in head by piping

Accident Summary Nr: 170093777 -- Report ID: 0636900 -- Event Date: 05/26/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
10892469705/27/199497110Dept. Of Defense - U.S. Afb - 301 Fw

Abstract: At approximately 3:45 p.m. on May 26, 1994, Employee #1 and another worker were installing a new air compressor. The other worker indicated that the air compressor had run for about a minute. The compressor was shut down to tighten some fittings, but noise was heard from the check valves. He turned the compressor off. The flexible metal hose failed, and a portion of the air supply piping fatally struck Employee #1 in the head.

Keywords: COMPRESSOR, HEAD, HOSE, PIPE, STRUCK BY, FLYING OBJECT, METAL PIPE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 108924697 Fatality Cut/Laceration Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.