Accident Summary Nr: 170093736 - Employee killed when crushed in flesher machine

Accident Summary Nr: 170093736 -- Report ID: 0636900 -- Event Date: 08/13/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
11004162108/14/199551590Texpac Hide & Skin Ltd.

Abstract: At approximately 1:40 a.m. on August 13, 1995, Employee #1, of Texpac Hide & Skin Ltd., was cleaning in the 10 1/2 ft heavy duty flesher area. Employee #1 was the operator of the flesher on the evening shift from 3:30 p.m. to midnight. He and a coworker were to clean the floor in this area following the shift. Another coworker, a member of the cleanup crew which worked from 10:30 p.m. to 2:00 or 3:00 a.m., was cleaning the flesher machine itself. Employee #1 was reaching into a gap of approximately 12 in. between a stationary drive shaft and an articulating drive shaft when the cleanup crew member, who was unaware of Employee #1's position, contacted a foot pedal, which caused the flesher to close. On closing, the articulated shaft rotated up and under the stationary shaft, catching and compressing Employee #1's head and killing him. The flesher was equipped with an electrically interlocked, 4-pedal, safety opening and closing system, which was designed to require near simultaneous (within 1 sec) contact of foot pedals by two operators at separate operating stations to initiate closing. Failure of a time delay relay in the safety system permitted employees performing cleanup to circumvent the system by jamming a wrench under one of the foot pedals. The flesher could then be closed by one employee activating the other foot pedals.

Keywords: HEAD, WORK RULES, CLEANING, FOOT CONTROL, INTERLOCK, LOCKOUT, CAUGHT BETWEEN, CRUSHED, COMMUNICATION, DRIVE SHAFT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 110041621 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close