Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170089627 - Employees caught in excavation cave-ins

Accident Summary Nr: 170089627 -- Report ID: 1054111 -- Event Date: 09/01/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
12377378009/01/199317940Hubco Excavation Inc

Abstract: Employees #1 and #2 were standing at the edge of a 9 1/2 foot deep excavation. The trench's side wall collapsed and Employee #2 fell into the trench. Employee #1 jumped in to assist Employee #2, was struck by a second cave-in, and also became trapped in the trench.

Keywords: EXCAVATION, PINNED, WORK RULES, CONSTRUCTION, TRENCH, SHORING, SLOPING, CAVE-IN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 123773780 Non Hospitalized injury Strain/Sprain Construction trades, n.e.c.
2 123773780 Hospitalized injury Fracture Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.