Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170088595 - Employee's arm injured when caught in out-feed power rolls

Accident Summary Nr: 170088595 -- Report ID: 1054119 -- Event Date: 06/10/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
12372302506/10/199252110Tree Products Manufacturing Inc

Abstract: At the time of the accident the firm was running a custom order for resizing Douglas Fir boards into 1 in. by 3 in. boards using a Yates A20 planer. Employee #1 was called over from the molder he was working on to help solve a problem with the planer. A small sliver of board was marring the planed finish of the resized boards at the outfeed. The planer feederman was manually cranking up the outfeed rolls when Employee #1 reached into the space between the roll infeed nip point and knife side heads to remove the sliver. His hand contacted the in-running rolls, which pulled his left hand and arm through the rolls. The feederman continued raising the roll to free Employee #1. First aid was administered to the employee and he was transported to the hospital. Employee #1's left hand and arm were saved, but are severely damaged.

Keywords: CLEANING, LOCKOUT, ROLLER--MACH/PART, CAUGHT BETWEEN, ARM, NIP POINT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 123723025 Hospitalized injury Bruise/Contus/Abras Wood lathe, routing, and planing machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close