Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170087332 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU GUY

Accident Summary Nr: 170087332 -- Report ID: 0626300 -- Event Date: 09/28/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
11630885909/28/199424490Texas Basket Company

Abstract: A guy had separated from its ground anchor and had contacted a 7200-volt overhead power line. An employee was electrocuted when he contacted the energized guy.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, E GI VII, ELECTROCUTED, GUY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 116308859 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close