Accident Summary Nr: 170087191 - ELECTRIC SHOCK - GROUND FAULT IN CRANE

Accident Summary Nr: 170087191 -- Report ID: 0626300 -- Event Date: 06/30/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
11631274507/02/199773890Tindall Record Storage

Abstract: An employee of a record storage company was retrieving a box of archived records for a rush order. He was operating a Hartman Cubestacker crane. The crane was powered by 480-volt three-phase runway conductors located near the ceiling. The employee had moved the crane about 9.1 meters down the aisle. The overhead collectors became misaligned and caused a ground fault. The employee was electrocuted.

Keywords: ELECTRICAL, E GI VII, ELECTROCUTED, RUNWAY CONDUCTOR, GROUND FAULT, EQUIPMENT GROUNDING, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 116312745 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.