Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170084495 - Employee killed when crushed by collapsing manlift

Accident Summary Nr: 170084495 -- Report ID: 0625400 -- Event Date: 06/11/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
12347620206/11/199650820Anderson Machinery Austin, Inc.

Abstract: Employee #1 was under the riser section of a Grove manlift. Because of a loss in hydraulic pressure through the hole for the holding valve on the lift cylinder, the riser fell on Employee #1. He was killed instantly by blunt force trauma to his legs, back, and chest. The valve was found on the undercarriage of the machine; it appeared that Employee #1 had removed it.

Keywords: HYDRAULIC LIFT, BOOM, COLLAPSE, CRUSHED, VALVE, AERIAL LIFT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 123476202 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.