Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170082432 - ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED CONDUCTOR

Accident Summary Nr: 170082432 -- Report ID: 0625700 -- Event Date: 11/04/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
10343360311/14/199486610Jimmy Swaggart Ministries

Abstract: An employee was changing air filters on a large, 480-volt, three-phase air exchanger unit located in a mechanical room on the second floor of a building. Instead of using a tool to remove the filter, the employee crawled inside a filter compartment to get to it. As he was doing this, he contacted an energized conductor in the compartment and was electrocuted. The equipment had not been locked out before the employee started to work on it.

Keywords: MAINTENANCE, E GI IV, ELECTRICAL, CONFINED SPACE, ELECTROCUTED, LOCKOUT, ELECTRIC CONDUCTOR, ELEC EQUIPMENT--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103433603 Fatality Electric Shock Not specified mechanics and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.