Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170081681 - Employee killed when crushed by falling bulkhead

Accident Summary Nr: 170081681 -- Report ID: 0625700 -- Event Date: 03/29/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
12346509804/01/199637310Trinity Marine (Equitable Shipyards)

Abstract: Employee #1, a shipfitter, was installing a 7 ft tall by 12 ft long, approximately 1,800 lb bulkhead into a deck section of a barge under construction. The bulkhead was supported in an upright position by two 5/16 in. thick by 6 in. wide by approximately 3 ft tall flat bar braces that were tack welded to longitudinal structural members. When the tack welds on one of the braces broke, the bulkhead fell and Employee #1 was crushed against another bulkhead. He was killed.

Keywords: BARGE, SHIPYARD, UNSECURED, WORK RULES, BROKEN WELD, CAUGHT BETWEEN, CRUSHED, STRUCK BY, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 123465098 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.