Accident Summary Nr: 170081335 - Iron worker killed in fall from roof

Accident Summary Nr: 170081335 -- Report ID: 0625700 -- Event Date: 06/18/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
10343435306/20/199517910Bamburg Steel Buildings, Inc.

Abstract: Employee #1, an iron worker, was working with a crew installing metal decking on the roof of a building 38 ft from the ground. Employee #1's task was to first put down sheets of styrofoam insulation, 1 in. thick by 4 ft by 20 ft, across the purlins (rafters) of the building, which were approximately 5 ft apart, then tape the seams together before metal decking was laid. Employee #1 stepped out on a 3 1/2 in. wide flange of purlin, and was taping the seams together, when he apparently lost his footing. He fell between the purlins to the ground. His head was fractured and he was killed.

Keywords: FRACTURE, HEAD, INSTALLING, IRON WORKER, WORK RULES, SLIP, CONSTRUCTION, RAFTER, FALL, FALL PROTECTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103434353 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close