Accident Summary Nr: 170070098 - Employee killed when struck by exploding tire

Accident Summary Nr: 170070098 -- Report ID: 0352430 -- Event Date: 02/09/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10842743611/01/199075380Action Auto Services

Abstract: Employee #1 was apparently trying to mount a 16 in. diameter Goodyear 7.50 x 16CT snow tire on a 16 1/2 in. rim. He was inflating the snow tire when it exploded, striking him in the head. The explosive force threw him approximately 12 ft above the floor. His head was crushed and he suffered severe brain damage. Employee #1 was killed.

Keywords: HEAD, BLOWOUT--TIRE, WORK RULES, EXPLOSION, RESTRAINING DEVICE, INFLATING, STRUCK BY, FLYING OBJECT, BRAIN, TIRE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 108427436 Fatality Concussion Automobile mechanics

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.