Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170068266 - Two employees injured in fall when scaffold collapses

Accident Summary Nr: 170068266 -- Report ID: 0352410 -- Event Date: 09/22/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
10445486309/23/199315210John R. Mulford & Son, Inc.

Abstract: On September 22, 1993, at approximately 10:45 a.m., employees of John R. Mulford & Son, Inc., were repairing the roof on a two story wood dwelling in Millington, MD. Employees #1 and #2 were installing shingles from an unguarded 14 inch Werner Task Master scaffold plank 18 feet high on a pump jack scaffold 30 feet in length. A third employee was climbing an extension ladder used to gain access to the left front of the scaffold. The right pole, 24 feet in height, approximately 4 inches in width, and consisting of two 16 foot 2 by 4s and two 8 foot 2 by 4s inches, failed 7 feet 10 inches from the bottom. As a result, the right side of the pump jack scaffold collapsed when the bracing at the top of the pole pulled out of the eave of the roof where it was attached with 16 penny nails. Employees #1 and #2 fell 18 feet to the ground while the third employee's ladder came to rest against the eave. Employee #1 received bruises and lacerations, and was treated and released. Employee #2 complained of back pain and was admitted for observation at Kent's Queen Ann Hospital. No one at the site was familiar with pump jack installation or inspection requirements.

Keywords: ROOF, WORK RULES, CONSTRUCTION, PUMP JACK SCAFFOLD, SCAFFOLD COLLAPSE, LACERATION, FALL, FALL PROTECTION, BRACING, UNTRAINED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 104454863 Non Hospitalized injury Cut/Laceration Roofers
2 104454863 Hospitalized injury Strain/Sprain Roofers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close