Accident Summary Nr: 170067557 - ELECTRIC SHOCK - CAUSE UNKNOWN

Accident Summary Nr: 170067557 -- Report ID: 0352420 -- Event Date: 09/23/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11953255409/24/199282110Harford County Public Schools

Abstract: AN EMPLOYEE WAS WORKING WITH A 208-VOLT, THREE-PHASE, 9.93-AMPERE HOBART DISHWASHER (MODEL NO. FR-36 U; SERIAL NO. 276401) IN A DISHWASHING ROOM. THE DISHWASHER HAD BEEN IN SERVICE FOR ONLY 3 DAYS FOLLOWING AN INCIDENT ON MAY 18, 1992, WHEN THIS EMPLOYEE HAD RECEIVED AN ELECTRIC SHOCK. FOLLOWING THAT INCIDENT, THE MACHINE HAD BEEN INSPECTED AND REPAIRED, AND IT WAS PUT BACK INTO SERVICE AFTER ANOTHER INSPECTION. THE EMPLOYEE WAS NOW USING THIS MACHINE FOR THE FIRST TIME SINCE IT HAD BEEN PUT BACK INTO SERVICE, AND SHE WORKED THE DISHWASHER THROUGH THE FIRST TWO LUNCH PERIODS. AFTER THE SECOND LUNCH PERIOD, SHE OPENED THE DOORS TO ALLOW IT TO COOL OFF WHILE SHE WAS TAKING HER LUNCH BREAK. WHEN SHE RETURNED FROM LUNCH, SHE HAD ANOTHER EMPLOYEE OPEN THE CIRCUIT BREAKER FOR THE DISHWASHER. THE CIRCUIT BREAKERS FOR THE HOT WATER BOOSTER AND FOR THE GARBAGE DISPOSAL REMAINED CLOSED, HOWEVER. THE EMPLOYEE WORKING WITH THE DISHWASHER HAD TAKEN OUT ALL OF ITS STRAINERS AND HAD DUMPED THE FOOD SCRAPS INTO THE GARBAGE DISPOSAL AREA. AS SHE REACHED TO PULL OUT THE LAST STRAINER SHE FELT AN ELECTRIC SHOCK GO THROUGH HER RIGHT ARM. SHE COULD NOT FREE HER GRIP BEFORE SHE LOST CONSCIOUSNESS. SHE WAS FOUND COMPLETELY BLUE AND JERKING, WITH HER RIGHT ARM UP TO THE ELBOW INSIDE THE MACHINE, BUT THE EMPLOYEES WHO FREED HER FROM THE MACHINE FELT NO ELECTRIC SHOCK. THE INJURED EMPLOYEE WAS GIVEN CARDIO-PULMONARY RESUSCITATION AND TAKEN TO A HOSPITAL, WHERE SHE WAS TREATED AND RELEASED. COUNTY OFFICIALS, TWO STATE OSHA COMPLIANCE STAFF MEMBERS, AN INDEPENDENT ENGINEERING CONSULTANT, AND A TECHNICIAN FROM HOBART EXAMINED THE MACHINE. NONE OF THE INSPECTIONS OR TESTS THEY PERFORMED FOUND ANYTHING WRONG WITH THE MACHINE OR THE SURROUNDING WORK AREA.

Keywords: ELECTRICAL, CPR, E GI VII, LOCKOUT, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC SHOCK, ELEC EQUIPMENT--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119532554 Hospitalized injury Electric Shock Kitchen workers, food preparation

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close