Accident Summary Nr: 170067276 - Employee killed when crushed by collapsing boom

Accident Summary Nr: 170067276 -- Report ID: 0352430 -- Event Date: 07/14/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
11953151507/14/199216220Richard F. Kline Inc.

Abstract: At 2:00 p.m. on July 14, 1992, Employee #1, a concrete finisher, was underneath a 20 ft long section of a lattice boom that was 60 ft long and attached to a 45-ton Link-Belt crawler, serial # 9LG5674, model 5-108B. He was removing the two bottom pins with a sledge hammer when the boom collapsed onto him. Employee #1 suffered multiple injuries and was pronounced dead at the scene. He had not been properly trained on the crane manufacturer's requirements for dismantling the boom section and had not blocked under the crane boom sections to prevent them from moving.

Keywords: DISMANTLING, BOOM, COLLAPSE, BLOCKS, CRANE BOOM, WORK RULES, CONSTRUCTION, CRUSHED, STRUCK BY, UNTRAINED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119531515 Fatality Other Concrete and terrazzo finishers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close