Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170061980 - Employee dies after struck by excavator

Accident Summary Nr: 170061980 -- Report ID: 0453720 -- Event Date: 11/10/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
12531158911/14/199516110Terry Brothers Construction Company, Inc.

Abstract: At approximately 11:40 a.m. on November 10, 1995, Employee #1 dismounted his rubber tire backhoe to direct a dump truck to a spot pointed out to him by a coworker. The coworker was operating a Komatsu PC 220LC multi-directional excavator to pack fill dirt over a culvert in Lenoir, NC. The excavator's boom bucket was on the south side of the excavator, and the operator was facing south and moving north in reverse. His vision was obstructed. Employee #1, who was not wearing a reflective vest, was struck by the excavator's west side tracks as he faced north directing the dump truck. Employee #1 sustained crushing injuries to his legs and pelvis. He died on November 11, 1995, at 5:40 p.m. The excavator's multi-directional alarm was not working and had not worked for more than two weeks.

Keywords: BACK-UP ALARM, INADEQUATE MAINT, OBSTRUCTED VIEW, WORK RULES, CONSTRUCTION, CRUSHED, PELVIS, EXCAVATOR, STRUCK BY, BACKING UP

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125311589 Fatality Other Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close