Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170060180 - Employee fractures vertebrae in fall from compactor

Accident Summary Nr: 170060180 -- Report ID: 0453710 -- Event Date: 10/05/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
12526915910/05/199599990County Of Bladen

Abstract: Employee #1 was working on top of a landfill trash compactor repairing the push plate retraction servo-cylinder. He lost his footing on the slippery walking surface and fell backward. His feet became entangled in the hydraulic service lines atop the vehicle. Employee #1 fell head first 8 ft 10 in. and suffered compressed fractures of four vertebrae in his lower neck and upper back.

Keywords: FRACTURE, REPAIR, BACK, LANDFILL, TRASH COMPACTOR, FALL, SLIPPERY SURFACE, ENTANGLED, LOST BALANCE, VERTEBRA

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125269159 Hospitalized injury Amputation Milling and planing machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.