Accident Summary Nr: 170055586 - Fifteen employees suffer carbon monoxide overexposure

Accident Summary Nr: 170055586 -- Report ID: 0453710 -- Event Date: 06/27/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
1849443506/28/199035350Turbo Conveyor

Abstract: On June 27, 1990, most of the first shift employees were inventorying the plant. Two propane-powered forklifts were being used to move parts from one end of the plant to the other to be weight-counted. The two spray booths in the plant were the only source of exhaust ventilation. They were shut off at 1:00 p.m. By this time, most of the employees had headaches. Symptoms including headaches, dizziness, and nausea became apparent between 3:00 p.m. and 4:00 p.m. The plant was evacuated at approximately 4:30 p.m. Employees #1 through #15 went or were taken to hospitals. No employees were admitted. Carboxyhemoglobin levels were 17.2 percent to 19.6 percent. Back calculation of exposure levels was 209 ppm to 257 ppm as 8 hours time weighted averages in air.

Keywords: VENTILATION, HEADACHE, INHALATION, NAUSEA, INDUSTRIAL TRUCK, DIZZINESS, EXHAUST FUMES, CARBOXYHEMOGLOBIN, OVEREXPOSURE, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18494435 Non Hospitalized injury Poisoning(Systemic) Assemblers
2 18494435 Non Hospitalized injury Poisoning(Systemic) Welders and cutters
3 18494435 Non Hospitalized injury Poisoning(Systemic) Welders and cutters
4 18494435 Non Hospitalized injury Poisoning(Systemic) Misc. electrical & electronic equipment repairers
5 18494435 Non Hospitalized injury Poisoning(Systemic) Welders and cutters
6 18494435 Non Hospitalized injury Poisoning(Systemic) Misc. metal,plastic,stone&glass-working mach. op's
7 18494435 Non Hospitalized injury Poisoning(Systemic) Punching and stamping press machine operators
8 18494435 Non Hospitalized injury Poisoning(Systemic) Welders and cutters
9 18494435 Non Hospitalized injury Poisoning(Systemic) Freight, stock and material handlers, n.e.c.
10 18494435 Non Hospitalized injury Poisoning(Systemic) Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.