Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170054399 - Employee's right arm caught in garnett machine

Accident Summary Nr: 170054399 -- Report ID: 0453710 -- Event Date: 10/18/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
1857173702/22/199022990Thomasville Fiber Co.

Abstract: Employee #1 was cleaning a garnett machine with an air hose. He had positioned himself within 1 ft of the machine and put the air nozzle and his right hand too close to a nip point between two card rollers. Employee #1's right arm was pulled into the machine. He required hospitalization.

Keywords: GARNETT MACHINE, CLEANING, ROLLER--MACH/PART, CAUGHT BETWEEN, ARM, NIP POINT, UNSTABLE POSITION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18571737 Hospitalized injury Fracture Knitting, looping, taping & weaving mach.operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.