Accident Summary Nr: 170053482 - Employee injured when crushed by manlift counterweight

Accident Summary Nr: 170053482 -- Report ID: 0950411 -- Event Date: 12/30/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30143912101/29/199973530Coker Equipment Co., Inc.

Abstract: Employee #1, a lift operator, left her car on the north lift and locked it out. She entered the fenced enclosure area at the base and then the south counterweight enclosure to grease the components of the north lift car. The south lift, which was still operating, ascended to the top level, bringing its 5,200 lb counterweight down to the lowest position. The south counterweight struck Employee #1 on her hard hat and crushed her against the buffer springs. She sustained injuries that required hospitalization.

Keywords: MAINTENANCE, COUNTERBALANCE, PINNED, WORK RULES, LOCKOUT, CRUSHED, STRUCK BY, ELEVATOR, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 301439121 Hospitalized injury Fracture Elevator operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.