Accident Summary Nr: 170046833 - Employee killed in trench cave-in

Accident Summary Nr: 170046833 -- Report ID: 1055320 -- Event Date: 08/04/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30214908308/04/199816290Anderson Excavation Inc

Abstract: At 2:15 p.m. on August 4, 1998, Employee #1 was spreading crushed rock in a 7 ft deep by 53 in. wide trench. The nearly vertical east wall caved in, burying Employee #1. He died of blunt force injuries to his head and chest. Employee #1 had been working 20 ft south of the trench box.

Keywords: COLLAPSE, WORK RULES, CONSTRUCTION, TRENCH, SLOPING, BURIED, CAVE-IN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Excavation, landfill Other $250,000 to $500,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 302149083 Fatality Asphyxia Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Trench collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.