Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170046312 - Employee's fingers amputated by die mounted in press brake

Accident Summary Nr: 170046312 -- Report ID: 1055320 -- Event Date: 10/07/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11121432611/12/199134330Travis Industries Inc

Abstract: Employee #1 was operating a Chicago 25-ton press brake, model #265, with a die mounted in it. The die trim used 4 in. to 7 in. sanding disks. Employee #1 was sitting on the edge of a stack of pallets with his foot resting on a trip pedal. He reached over to adjust a disk's in-trimmer, putting pressure on the foot pedal and tripping the press brake. His ring and middle fingers were amputated to the first knuckle, as well as the tip of his index finger.

Keywords: DIE, AMPUTATED, PRESS BRAKE, FINGER, WORK RULES, FOOT CONTROL, POINT OF OPERATION, FOOT-POWERED PRESS, PRESS OPERATOR, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111214326 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close