Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170042055 - Two employees injured in fall when scaffold plank breaks

Accident Summary Nr: 170042055 -- Report ID: 1055320 -- Event Date: 12/31/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11148381412/31/199017510Western Exteriors

Abstract: At about 1:30 p.m. on December 31, 1990, Employees #1 and #2, of Western Exteriors, Edmonds, WA, were working on the walls of a new apartment project. They entered a Wall Climber suspended scaffold, model 8180D, from opposite ends of the metal framed painter's plank that was suspended between two telescoping posts spaced approximately 19 1/2 ft apart. Employee #1 requested that Employee #2 help him tie a lifeline to his safety belt. Employee #2, who was not wearing his body harness, walked toward Employee #1. They were near the middle of the plank when it suddenly snapped and both employees fell approximately 33 ft to the ground. Employee #1 fractured his hip and left foot. Employee #2 struck the half of the plank that had landed on a pile of rocks, fracturing his right foot. The plank, which did not have a manufacturer's label on it, may have failed due to a combination of age, overloading, and a recent change from freezing to warmer weather.

Keywords: FRACTURE, INADEQUATE MAINT, OVERLOADED, CONSTRUCTION, PLANK, FALL, FALL PROTECTION, HIP, FOOT, SCAFFOLD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111483814 Hospitalized injury Fracture Construction trades, n.e.c.
2 111483814 Hospitalized injury Fracture Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close