Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170034029 - Employee killed by flying diaphragm

Accident Summary Nr: 170034029 -- Report ID: 0112000 -- Event Date: 10/08/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
10982925910/08/199239990A-1 Machining Company, Inc.

Abstract: Employee #1 was hit by one of two halves of a split diaphragm that weighed approximately 4,850 lb. Half of the diaphragm flew off from a vertical turret lathe while Employee #1 was cleaning. He died the next day. The securing device for the diaphragm on the VTL was inappropriate. Employee #1 had increased the machine table speed from 125 rpm to the maximum 270 rpm.

Keywords: LATHE, ROTATING PARTS, UNSECURED, WORK RULES, CLEANING, EQUIPMENT FAILURE, STRUCK BY, FLYING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 109829259 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.