Accident Summary Nr: 170022818 - Employee dies of anoxia after inhaling nitrogen gas

Accident Summary Nr: 170022818 -- Report ID: 0213400 -- Event Date: 03/15/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
10988245603/16/199528340Ciba Pharmaceuticals

Abstract: At approximately 12:55 p.m. on March 15, 1995, Employee #1, a chemical operator at Ciba-Geigy in Summit, NJ, was found slumped in the manway of reactor XR30. According to the batch sheet, the employee had been dry charging bromoketone powder into the nitrogen-inerted reactor. The medical examiner determined that the employee died of cerebral anoxia due to inhaling nitrogen gas.

Keywords: OXYGEN DEFICIENCY, ASPHYXIATED, REACTOR, VENTILATION, WORK RULES, INHALATION, GAS, NITROGEN, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 109882456 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.