Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170015705 - Two employees struck by falling wall

Accident Summary Nr: 170015705 -- Report ID: 1055320 -- Event Date: 09/22/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30217790209/23/199917110Active Concrete Inc

Abstract: At approximately 11:00 a.m. on September 22, 1999, Employees #1 and #2 and 16 coworkers were raising a 12 ft tall by 60 ft long wall. They were able to raise the wall to an approximately 45 degree angle, but could not raise it into a vertical position because it was too tall. When several of the workers left to get bracing, and the remaining employees were unable to hold up the wall. They let it fall and scrambled back to get out of the way. Employees #1 and #2 were unable to get clear in time and were struck by the falling wall. Employee #1 suffered a dislocated hip and Employee #2 suffered a dislocated shoulder. Both were hospitalized.

Keywords: SHOULDER, WALL, UNSECURED, WORK RULES, CONSTRUCTION, DISLOCATED, MANUAL MAT HANDLING, FALL, STRUCK BY, HIP
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building New project or new addition Under $50,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 302177902 Hospitalized injury Dislocation Occupation not reported
2 302177902 Hospitalized injury Dislocation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.