Accident Summary Nr: 169279.015 - Employee is struck by disk blade fragment during stone cutti

Accident Summary Nr: 169279.015 -- Report ID: 0418200 -- Event Date: 08/02/2024
Inspection NrDate OpenedSICNAICSEstablishment Name
1768984.01508/15/2024327991Atl Granite Installers & Fabricators Llc

Abstract: At 11:00 a.m. on August 2, 2024, Employee #1, a stone countertop installer, was cutting small holes in a quartz slab using a Makita Angle Grinder Model 9564CV, Serial Number 620119A. The grinder, which did not have a guard installed, uses abrasive cut-off wheels that rotate at speeds of up to 10,500 RPM. A piece of the cutting wheel edge broke away and lodged into the employee's head through the right cheek. The injury resulted in a traumatic brain injury secondary to disk blade fragment intrusion. Employee #1 was transported to the hospital and later died from the brain injury while at the hospital.

Keywords: Blade, Brain, Cutting, Grinder, Grinding Wheel, Grinding Wheel Exploded, Machine Guarding, Stone, Struck Against, Struck By, Traumatic Brain Injury, Unguarded

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1768984.015 22 M Fatality Brickmasons and stonemasons apprentices

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close