Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 169239.015 - Employee is killed when trapped by moving conveyor belt

Accident Summary Nr: 169239.015 -- Report ID: 0950625 -- Event Date: 08/13/2024
Inspection NrDate OpenedSICNAICSEstablishment Name
1768689.01508/14/2024115115Reyes And Hall Inc.

Abstract: At 9:40 p.m. on August 13, 2024, Employee #1 was clearing debris from an elevated conveyor belt machine. While standing on the conveyor belt to check if debris had been cleared, the conveyor belt was unexpectedly energized. Employee #1 fell and became trapped between a metal bar, which was a structural part of the conveyor belt, and the moving conveyor belt. The employee sustained fatal chest compression injuries and was pronounced dead at the scene.

Keywords: Asphyxiated, Belt Conveyor, Blunt force, Blunt force trauma, Chest, Clearing, Conveyor, Debris, Lockout/Tagout, Metal, Metal Bar, Moving, Moving Object, Tagout, Trapped

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1768689.015 54 M Hospitalized injury Equipment Operator: Heavy

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.