Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 167327.015 - Employee dies of head injuries when caught by rolling metal

Accident Summary Nr: 167327.015 -- Report ID: 0729700 -- Event Date: 06/10/2024
Inspection NrDate OpenedSICNAICSEstablishment Name
1754212.01506/11/2024331210Atchison Tubular Manufacturing

Abstract: At 10:45 a.m. on June 10, 2024, an employee working as a machine operator for a metal pipe manufacturer working alone inside the trim building. The employee was trimming pipes and doing stenciling in a non-stenciling location near the out rack. As part of the process, 2,600-pound pipes roll out of the trimmer building towards the end of the out rack. The employee was caught between 2,633 pounds of metal pipe on the trim out rack from behind while stenciling. The employee died from crush injuries and lacerations, including head injuries.

Keywords: Caught Between, Caught By, Crushed, Cutting, Head, Laceration, Machine operator, Metal Pipe, Rolling, Storage Rack, Unguarded, Unsafe Position

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1754212.015 30 M Fatality Milling and planing machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close