Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 166723.015 - Employee is killed due to machinery activation during mainte

Accident Summary Nr: 166723.015 -- Report ID: 0830600 -- Event Date: 05/15/2024
Inspection NrDate OpenedSICNAICSEstablishment Name
1749375.01505/16/2024423820Ag Tech Llc.

Abstract: At 9:30 a.m. on May 15, 2024, Employee #1 was performing maintenance on a baler machine, lubricating its gears before the equipment was scheduled for delivery to a customer. During the procedure, the machine's stuffer arm unexpectedly activated, striking the employee in the head and causing fatal blunt force trauma.

Keywords: Automatic Machine, Baler, Blunt force trauma, Gear, Head, Lockout/Tagout, Maintenance, Struck By

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1749375.015 45 M Fatality Farm equipment mechanics

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.