Accident Summary Nr: 163921.015 - Employee dies of head and neck injuries in fall from catwalk

Accident Summary Nr: 163921.015 -- Report ID: 0950643 -- Event Date: 02/06/2024
Inspection NrDate OpenedSICNAICSEstablishment Name
1726774.01502/06/2024512110Radford Studio Center Llc

Abstract: At 6:50 a.m. on February 6, 2024, an employee was working as an engineering technician for a television and film production company. The employee was working with a crew which included Employee #1 and Employee #2. The crew was working on wooden catwalks located in Stage 3. The crew was collecting and removing lighting cable equipment that was hanging from the wooden platforms. One platform was accessible via a wooden staircase that continued upward and was connected to the other wooden catwalk platforms. The walking surface of these catwalks consisted of wooden floorboards of various sizes, including as 2-inch by 6-inch and 2-inch by 8-inch boards. These floorboards were supported underneath by 2-inch by 4-inch wooden supports (sometimes referred to as "ledgers"). A particular section of this catwalk had a deteriorated ledger that was not bearing the 4-inch by 12-inch underlying support beam, but instead was improperly nailed to a roof truss. The deteriorated ledger was weakened likely due to age, environmental conditions and repeated stress loads over many decades. As the crew walked along the catwalks, the employee stood on the weakened section of catwalk. Suddenly, and without warning, the ledger supporting the floorboard broke apart and collapsed as the employee was standing on this section of catwalk. The employee fell 41 feet and forcefully impacted the ground below. The employee was pronounced dead by responding emergency medical services shortly after the fall. The cause of death was blunt force trauma to the head, neck and legs.

Keywords: Blunt force, Blunt force trauma, Board, Catwalk, Elevated Work Platform, Engineer, Fall, Fall From Elevation, Fall Protection, Floor Opening, Ground, Head, Inadequate Maint, Injury Illness Prevention Program, Leg, Maintenance, Movie, Neck, Platform, Raised platform, Walking Surface, Weather, Wood, Wood Board, Work Surface

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1726774.015 41 M Fatality Industrial engineering technicians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.