Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 163436.015 - Employee is killed when struck by trailer

Accident Summary Nr: 163436.015 -- Report ID: 0627510 -- Event Date: 09/26/2023
Inspection NrDate OpenedSICNAICSEstablishment Name
1722978.01501/24/2024237120Ferguson Construction Company

Abstract: At 7:05 a.m. on September 27, 2023, an employee was attempting to move a piece of a heavy equipment trailer with a John Deere excavator. The trailer struck the employee, who suffered blunt force trauma to the chest and abdomen. The employee was killed.

Keywords: Abdomen, Blunt force trauma, Chest, Excavator, Struck By, Trailer
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline New project or new addition   X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1722978.015 52 M Fatality Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.