Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 163180.015 - Employee is killed when crushed by forklift

Accident Summary Nr: 163180.015 -- Report ID: 0418800 -- Event Date: 01/13/2024
Inspection NrDate OpenedSICNAICSEstablishment Name
1721220.01501/16/2024444130Nachon Enterprises, Inc.

Abstract: At 8:51 a.m. on January 13, 2024, an employee had just picked up a pallet of rebar for a client and parked the forklift outside of the yard. The employee got off the forklift to shut the gate and did not turn the forklift off or set the emergency brake. As the employee attempted to secure the gate, the forklift began to roll and crushed the employee between the concrete wall and the forklift. The employee's torso was crushed and split open, which resulted in his death.

Keywords: Brake, Caught Between, Concrete, Crushed, Forklift, Gate, Pallet, Rebar, Roll, Torso, Wall

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1721220.015 68 M Fatality Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.