Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 162993.015 - One employee is killed, another employee injures pelvis and

Accident Summary Nr: 162993.015 -- Report ID: 0524700 -- Event Date: 01/08/2024
Inspection NrDate OpenedSICNAICSEstablishment Name
1719995.01501/08/2024488999K&M Transport, Llc

Abstract: On January 8, 2024, a three man teardown crew was in the process of preparing a mobile home for transport by semi-truck to another mobile home park. At approximately 10:00 a.m., the crew was preparing to lift the mobile home from its foundation, which consisted of fourteen cinder block pillars on a recycled gravel/stone foundation pad, to attach wheels to the home axles and frame for roadway transport. Employee #1 and Employee #2 crawled under the mobile home and placed four 20-ton pneumatic jacks onto the frame and I-Beams of the mobile home. At approximately 10:30 a.m., a laborer began lifting the four pneumatic bottle jacks by using a single airline connected to a single air compressor, using a multi-line air compressor manifold. As the mobile home was being lifted by the laborer, Employee #1 and Employee #2 were partially underneath the mobile home making adjustments and removing the existing cinder block pillars. At approximately 10:45 a.m., the mobile home became displaced and fell down, crushing and pinning both Employee #1 and Employee #2 under the mobile home. The laborer called EMS. Employee #1 was pronounced dead on the scene, and Employee #2 was transported by air ambulance to a level one trauma center. Employee #2 was hospitalized to treat crushing injuries to the pelvis and hips and internal bleeding.

Keywords: Crushed, Falling Object, Hip, Internal Bleeding, Mobile Home, Pelvis, Pinned, Pneumatic, Pneumatic equipment, Semi Tractor Trailer
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling Demolition   1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1719995.015 57 M Hospitalized injury Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Demolition
Fatality Cause:
2 1719995.015 37 M Fatality Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Demolition
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.