Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 161426.015 - Employee is killed when run over by bulldozer

Accident Summary Nr: 161426.015 -- Report ID: 0453710 -- Event Date: 09/29/2023
Inspection NrDate OpenedSICNAICSEstablishment Name
1701114.01509/29/20231610237310155292 - Thalle Construction Co., Inc.

Abstract: At 12:00 a.m. on September 29, 2023, an employee was operating a John Deere bulldozer. He exited the bulldozer while it was still moving and was fatally crushed when the bulldozer ran over him.

Keywords: Blunt force trauma, Bulldozer, Crushed, Operating, Run Over, Struck By, Vehicle In Gear

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1701114.015 57 M Fatality Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close