Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 160589.015 - Two employees are killed after explosion

Accident Summary Nr: 160589.015 -- Report ID: 0627500 -- Event Date: 10/07/2023
Inspection NrDate OpenedSICNAICSEstablishment Name
1702090.01510/07/2023484220Axis Transport, Llc

Abstract: At 10:00 a.m. on October 7, 2023, three employees were preparing to install a male threaded pipe sleeve into a female threaded factory installed coupling on a flange to interconnect three battery tanks from the tank roof. Two days prior to welding, there was a liquid leak from one of the tanks. The supervisor was instructed by the plant manager to open the vessel to purge the mud. The supervisor instructed his employees to shut off the valves once they were installed. However, there still appeared to be fluid leaking from the tank, as stated by the plant manager. The supervisor's crew installed the valves upside down, thus leaving the valves open. This occurrence led to gas leaking into the tanks. There were three employees working on top of the tank. The supervisor did not conduct any flammable testing prior to welding. There was an explosion. During the explosion, the lid and two of the employees were thrown. Employee #1 and Employee #2 were pronounced dead at the scene. A coworker jumped over to the other tank prior to the explosion; he was rescued alive with no injuries. Only one of the three employees was utilizing fall protection at the time of the incident. The aerial lift that was being utilized had a burned and wilted basket with a missing gate. The tank that the employees were installing flanges on was missing the lid.

Keywords: Aerial Lift, Battery, Couplings, Explosion, Fall, Fall From Elevation, Fall Protection, Flammable Vapors, Flange, Gas Leak, Leak, Purging, Shut-Off Valve, Tank, Valve, Welding
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction New project or new addition   20 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1702090.015 57 M Fatality Distance of Fall: 20 feet
Worker Height Above Ground/Floor: 20 feet
Cause: Other Activities-Installing Ornamental And Archite
Fatality Cause:
2 1702090.015 30 M Fatality Welders and cutters Distance of Fall: 20 feet
Worker Height Above Ground/Floor: 20 feet
Cause: Other Activities-Installing Ornamental And Archite
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.