Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 158318.015 - One employee is killed, another is treated for toluene overe

Accident Summary Nr: 158318.015 -- Report ID: 0627100 -- Event Date: 07/20/2023
Inspection NrDate OpenedSICNAICSEstablishment Name
1685229.01507/21/2023238190Luis Roldan

Abstract: On July 20, 2023, Employee #1 and Employee #2, both construction laborers, were waterproofing the basement walls of a residence. They were digging a trench and looking for leaks using toluene. One employee lost consciousness and the other entered the excavation in a rescue attempt, but also lost consciousness. The employees' family members were alerted when they did not return home and went looking for them around 7:30 p.m. At 9:30 p.m., they called the fire department after the employees were found unconscious. The fire department took atmospheric readings and donned their SCBAs to perform the rescue. Employee #1 died and Employee #2 was hospitalized to treat asphyxia and inhalation of toluene vapors.

Keywords: Asphyxiated, Chemical, Chemical Exposure, Chemical Vapor, Confined Space, Entry Permit, Excavation, Laborer, Lack of oxygen, Leak, Loss of consciousness, Misjudgment, Misjudgment of Hazardous Situation, Multi-employer Worksite, Multiemployer, Overexposure, PPE, PPE Hazard Assessment, Respirator, Respiratory, Respiratory Tract, Toluene, Unauthorized Entry, Unconsciousness, Water, Waterproofing
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling Alteration or rehabilitation   8 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1685229.015 32 M Fatality Construction Laborer Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause:
2 1685229.015 30 M Hospitalized injury Construction Laborer Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.