Accident Summary Nr: 158203.015 - Employee is killed when dozer rolls over

Accident Summary Nr: 158203.015 -- Report ID: 0950652 -- Event Date: 06/22/2023
Inspection NrDate OpenedSICNAICSEstablishment Name
1678851.01506/22/2023212321Lb3 Enterprises Inc.

Abstract: At 2:45 p.m. on June 22, 2023, Employee #1 was operating a CAT D9T dozer on top of the 380 Bench in the mine quarry, preparing it for pre-blast drilling. Employee #1 was removing large rocks to flatten the bench area in preparation for the drilling rig to enter the bench. The 380 Bench did not have any visual references, such as berms, delineators, signs or other indicators, to identify the edges. After a push of materials to the southwest edge, Employee #1 reversed the dozer approximately 30-40 feet before making a turn towards the northeast. Employee #1 did not slow down or stop before rolling over the edge of the high wall at an approximate 40 to 45-degree angle to the direction of the high wall edge. The dozer rolled onto its right side and stopped upside down on the roll-over-protection system frame above the operator's cab and against a boulder. The roll was approximately 40 feet downward to the 320 Bench. Employee #1 was not wearing a safety belt, which allowed him to fall out of the operator's seat downwards into the cab's roof, and he suffered fatal head and neck injuries. Paramedics pronounced Employee #1 dead on arrival.

Keywords: Dozer, Head, Neck, Roll-Over, Seat Belt

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1678851.015 60 M Fatality Equipment Operator: Heavy

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close