Accident Summary Nr: 153943.015 - One is killed, thirteen are injured in explosion

Accident Summary Nr: 153943.015 -- Report ID: 0522300 -- Event Date: 02/20/2023
Inspection NrDate OpenedSICNAICSEstablishment Name
1651937.01502/20/2023331492I Schumann & Co. Llc

Abstract: At 2:20 p.m. on February 20, 2023, employees were conducting maintenance on furnace 5. While maintenance personnel were inspecting a water leak at the No. 5 Rotary Furnace, the furnace moved, encapsulating water in the liquid molten metal bath and causing a steam explosion. The furnace was not locked out at the time the maintenance personnel were inspecting the furnace. One employee was killed and 13 were hospitalized to treat burns and struck by injuries from the explosion.

Keywords: Burn, Explosion, Explosion Venting, Falling Object, Furnace, Lockout, Lockout/Tagout, Maintenance, Steam, Struck By

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1651937.015 46 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.