Accident Summary Nr: 153139.015 - Employee is killed when crushed by loader boom

Accident Summary Nr: 153139.015 -- Report ID: 0854910 -- Event Date: 01/19/2023
Inspection NrDate OpenedSICNAICSEstablishment Name
1645572.01501/19/2023213112Gough Pro Services, Llc

Abstract: At 10:45 a.m. on January 19, 2023, an employee was replacing the hydraulic cylinder on the boom of a front-end loader when he disconnected the hydraulic line to the boom cylinder while the loader boom was in the air. The loader boom dropped suddenly crushing employee's torso between the boom and front differential. The employee died due to his injuries.

Keywords: Boom, Crushed, Crushing, Dropped, Front End Loader, Hydraulic Cylinder, Removing

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1645572.015 46 M Fatality Heavy equipment mechanics

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.