Accident Summary Nr: 152006.015 - Employee is killed when crushed by hydraulic lift table

Accident Summary Nr: 152006.015 -- Report ID: 0627100 -- Event Date: 12/10/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1638371.01512/11/2022336212Utility Trailer Manufacturing Company

Abstract: At 6:20 a.m. on December 10, 2022, Employee #1 was working with a coworker on the hydraulics for a hydraulic lift table when they removed a connection to the hydraulic pump allowing fluid to escape. The table came down bending Employee #1 over at waist and causing multiple fatal fractures and internal injuries. The coworker was smaller framed and suffered minor injuries.

Keywords: Connector, Crushed, Dropped, Fracture, Hydraulic, Hydraulic Fluid, Hydraulic Pump, Hydraulic Table, Internal Injuries, Leak, Removing, Repair, Table

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1638371.015 47 M Fatality Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.